Availability: | |
---|---|
Quantity: | |
Installation size
Parameter
Specifications | Technique |
Output specification | 4 ~ 20mA |
Output linear | Better than 0.05% |
Comprehensive accuracy | Better than 0.05% |
Input load | 1-4 sensors |
AD sampling | 40 SPS |
Output ripple | ≤5 mVp-p |
Output load | ≤500 Ω |
Excitation voltage | 5VDC |
Power supply | 15 ~ 26 VDC |
Power waste | ≤0.2 W |
Service temperature range | -20 ~ 60 ℃ |
Weight approx | 0.45 kg |
Material | Aluminum Alloy |
IP Class | IP 66 |
Features and Applications
Use special waterproof joint
Compensation adjustment adopts highly stable multi-turn potentiometer
The cover plate has waterproof rubber gasket, waterproof and dustproof, suitable for industrial sites with harsh environmental conditions
Prevent damage to the sensor caused by induced lightning and surge signals
Four in one out junction box
Multiple signal integration
Download T097.pdf