Material: | |
---|---|
Size: | |
Availability: | |
Quantity: | |
T103
Right
Compression
1N~100N, 100N~1000N, 1KN ~20kN
IP67, IP68
● Features and Applications
Low height, small deformation, small size;
Stainless steel material, protection grade: IP67, customizable IP68;
High temperature performance can be customized for injection molding, extrusion and other manufacturing processes;
Automotive press assembly, automated assembly, 3C product testing, new energy product assembly, medical testing,
In the field of robots, mold assembly and other industrial test, measurement and control systems;
High precision, good long-term stability, good reliability, fatigue resistance, high frequency of use, good creep performance, small temperature drift, high dynamic response frequency;
● Dimension
● Parameter
Capacity | 50,100,200,300,500,1000 N |
Sensitivity | 1.0 ± 20 % mV / V |
Zero Balance | ± 2% F.S. |
Non-linearity | 0.5% F.S. |
Hysteresis Error | 0.2% F.S. |
Repetition | 0.2% F.S. |
Creep (30 min) | 0.2% F.S. |
Temp. Effect on sensitivity (TKc) | 0.05% F.S./10℃ |
Temp. Effect on zero balance (TKo) | 0.05% F.S./10℃ |
Input Resistance | 800 ~ 1100 Ω |
Output Resistance | 800 ~ 1100Ω |
Insulating Resistance | ≥5000MΩ / 100VDC |
Excitation Voltage | 5 ~ 12 V |
Max. Excitation Voltage | 15 V |
Compensation Range | -10 ~ 60 ℃ |
Service Temperature Range | -20 ~ 80 ℃ |
Limit load (EL) | 150% F.S. |
Breaking load (Ed) | 200% F.S. |
Cable Size | φ2 × 4000 mm |
Material (Measuring element) | Stainless steel |
Weight (G), approx. | 28g |
IP Class | IP 67 (customizable) |
● Load Direction ● Wiring Code
● Download T103.pdf