Material: | |
---|---|
shape: | |
Availability: | |
Quantity: | |
T704
Right
Weighing
100N~1000N
IP68
Dimension
Parameters
Specifications | Technique |
Capacity | 10,20,50,100 kg |
Accuracy | C3 |
Zero Balance | 2.0 ± 10% mV / V |
Non-linearity | ± 5% F.S. |
Hysteresis Error | 0.0166% F.S. |
Repetition | 0.018% F.S. |
Creep (30 min) | 0.0166% F.S. |
Temp. Effect on sensitivity (TKc) | 0.0175% F.S. / 10 ℃ |
Temp. Effect on zero balance (TKo) | 0.0125 % F.S. / 10 ℃ |
Input resistance | 390 ± 5 Ω |
Output resistance | 350 ± 5 Ω |
Insulating Resistance | ≥5000 MΩ / 100VDC |
Excitation Voltage | 5 V |
Max. Excitation Voltage | 12 V |
Compensation Range | -10 ~ 40 ℃ |
Service Temperature Range | -10 ~ 50 ℃ |
Limit load (E L) | 150% F.S. |
Breaking load (E d) | 300% F.S. |
Cable size | φ5.4 × 3000 mm |
Weight (G), approx. | 0.5 kg |
Material (Measuring element) | Stainless steel |
IP Class | IP68 |
Features and Applications
Stainless steel material, good stability
Suitable for various environments, IP 68
Mainly used in various industrial weighing systems such as the food and medical industry
Load Direction
Wiring Code
Download T704 .pdf