Material: | |
---|---|
Exterior: | |
Availability: | |
Quantity: | |
R119
Right
Tension & Compression
1N~100N, 100N~1000N, 1KN ~20kN, 20kN ~
IP66
Dimension
Parameters
Specifications | Technique |
Capacity | 0.05,0.1,0.2,0.5,1,2,5,10,20,50,100 kN |
Sensitivity | 2.0 ± 10 % mV / V |
Zero Balance | ± 0.05 mV / V |
Non-linearity | 0.1% F.S. |
Hysteresis Error | 0.1% F.S. |
Repetition | 0.1% F.S. |
Creep (30 min) | 0.05% F.S. |
Temp. Effect on sensitivity (TKc) | 0.05% F.S. / 10 ℃ |
Temp. Effect on zero balance (TKo) | 0.05% F.S. / 10 ℃ |
Input Resistance | 385 ± 10 Ω |
Output Resistance | 350 ± 10 Ω |
Insulating Resistance | ≥5000 MΩ / 100VDC |
Excitation Voltage | 5 ~ 15 V |
Max. Excitation Voltage | 20 V |
Compensation Range | -10 ~ 60 ℃ |
Service Temperature Range | -20 ~ 80 ℃ |
Limit load (E L) | 150% F.S. |
Breaking load (E d) | 200% F.S. |
Cable Size | φ3 × 4000 mm |
Weight (G), approx. | 0.3 kg |
Material (Measuring element) | Stainless steel |
IP Class | IP66 |
Features and Applications
Low height, small deformation, small size and large range;
stainless steel material;
High dynamic response frequency;
Protection grade: IP65 can be customized;
Automotive press assembly, automated assembly, 3C product testing, new energy product assembly, medical testing, robotics,
Mold assembly and other industrial test, measurement and control systems
Load Direction
Wiring Code
Download R119 .pdf