Material: | |
---|---|
Exterior: | |
Availability: | |
Quantity: | |
T317
Right
Tension & Compression
1N~100N, 100N~1000N, 1KN ~20kN
IP66
Dimension
Parameters
Specifications | Technique |
Capacity | 20,50,100,300,500,1000,2000 N |
Sensitivity | 2.0 ± 10 % mV / V |
Zero Balance | ± 2% F.S. |
Non-linearity | 0.05% F.S. |
Hysteresis Error | 0.05% F.S. |
Repetition | 0.05% F.S. |
Creep (30 min) | 0.05% F.S. |
Temp. Effect on sensitivity (TKc) | 0.05% F.S. / 10 ℃ |
Temp. Effect on zero balance (TKo) | 0.05% F.S. / 10 ℃ |
Input Resistance | 650/350 ± 10 Ω |
Output Resistance | 650/350 ± 10 Ω |
Insulating Resistance | ≥5000 MΩ / 100VDC |
Excitation Voltage | 5 ~ 12 V |
Max. Excitation Voltage | 15 V |
Compensation Range | -10 ~ 60 ℃ |
Service Temperature Range | -20 ~ 80 ℃ |
Limit load (EL) | 150% F.S. |
Breaking load (Ed) | 200% F.S. |
Cable Size | φ3 × 4000 mm |
Weight (G), approx. | 0.1 kg |
Material (Measuring element) | Stainless steel |
IP Class | IP66 |
Features and Applications
Low height, small deformation, easy installation, flat loading;
stainless steel material;
Tension and compression
High dynamic response frequency;
Used in push and pull gauges, various industrial weighing systems, etc .;
Mainly used for automobile press assembly, automated assembly, 3C product testing, new energy product assembly, medical testing, robots,
Mold assembly and other industrial test, measurement and systems.
Load Direction
Wiring Code
Download T317.pdf